Filter By

Brand

Brand

Type

Type

Boilers Smoke Probes

Active filters

  • Type: Compatible
  • Smoke probe Junkers boiler Ceraclass Smart,...

    €25.00

    Smoke probe Junkers boiler

    The smoke probe is part of the Junkers boiler spare parts and it can be installed of the following boilers, although it may change depending on the specific serial number:

    • ZWA 24-1 A
    • ZWA 24-1 AB
    • ZWA 24-1/3 AB
    • ZWA 24-1 AI
    • ZWA 24-1/3 AI
    • ZWA 24-1 AM
    • ZWA 24-1 K
    • ZWA 24-1 KM
    • ZWA 28-1 AB
    • ZWA 28-1 AI
    • ZWA 28-1/3 AI
    • ZWA 28-1 AM
    • ZWE 24-1 KP
    • ZWE 24-2 KP
    • ZWE 24-2 AE
    • ZWE 24-3 MFK
    • ZWE 24-4 HA
    • ZWE 24-4 HK
    • ZWE 28--3 MFA
    • Various models

    In order to avoid the purchase of wrong products, we suggest to send the identification label of your boiler to our customer service via email or whatsapp.

    Last items in stock
  • Smoke probe Buderus boiler Logamax U022...

    €25.00

    Smoke probe Buderus boiler

    The smoke probe is part of the Buderus boiler spare parts and it can be installed of the following boilers, although it may change depending on the specific serial number:

    • Logamax U022-24 KB
    • Logamax U022-28 KB
    • Logamax U022-24 KI
    • Logamax U022-28 KI

    In order to avoid the purchase of wrong products, we suggest to send the identification label of your boiler to our customer service via email or whatsapp.

    Last items in stock
  • Smoke probe Chaffoteaux boiler Celtic, Cerar,...

    €17.00

    Smoke probe Chaffoteaux boiler

    The smoke probe is part of the Chaffoteaux boiler spare parts and it can be installed of the following boilers, although it may change depending on the specific serial number:

    • Celtic
    • Cerar Venti FF/FF Top
    • Cerar Venti NAT
    • Cerar Venti Top FFa/NAT
    • Cerar Ventiquattro Top
    • Cortina Pensotti
    • M20 e Novogas
    • M20 FF Novogas
    • MC 13-20
    • Multi Venti Top
    • Multi Ventiquattro Top
    • RS 20 M
    • RS 24 M
    • RS 20 Me

    In order to avoid the purchase of wrong products, we suggest to send the identification label of your boiler to our customer service via email or whatsapp.

La sonda fumi caldaia rileva la temperatura che passa nel condotto fumi. Nel caso in cui il valore rilevato sia anomalo, la scheda procede a mandare in blocco la caldaia e apparirà sul display l’errore sonda fumi. Infatti, se ad esempio i fumi hanno temperatura troppo elevata, a causa del loro ristagno all’interno del condotto, se la caldaia non andasse in blocco, la temperatura aumenterebbe fino a fondere alcuni elementi.